PKYDRIP FERTIGATION SYSTEMS

From replacing manual work to professional crop systems

One fertigation control platform, offered as Easy, Standard and Professional series, plus OEM white-label supply. The full range supports 3–6 nutrient channels and irrigation-zone management.

  • 3–6nutrient channels
  • Standardzone management
  • S/Pprecision dosing
Product family main photo Place an E / S / P series group photo here Recommended size: 1600 × 1200 px, light or transparent background
Dedicated control boardZone valve controlVFD pump controlEC / pH closed loopCloud and system integration
Deployed in 5 countries100+ installationsOEM partners in UAE, Australia & Russia

SELECTION GUIDE

Fertigation Product Selection Guide

Choose the management level, nutrient channels and interface first. Confirm flow, pressure, zones, power and connectivity before ordering.

  • Mainline flow and pressure
  • Irrigation zones and valve quantity
  • Power supply
  • Fertilizer stock solution and expected dosing capacity
  • Local-only or remote connectivity
  • Environmental-control and weather-station integration
Recommended model PKYDrip-S05

5 nutrient channels / EC-pH closed loop / 7-inch standard touchscreen

The public model stays short. Interface suffixes -07 / -10 appear on quotations only. View product details

PRODUCT RANGE

Four product paths, one clear choice

Series differences sit in control depth, data capability and integration — not in a wall of unexplained parameters.

E
EASY

Let automation replace repetitive manual work

For stable fertilizer programs and budget-sensitive sites. Pump start, dosing and valve switching become a dependable, easy-to-learn automatic sequence.

  • 3–6 channel proportional or timed dosing
  • Local automatic operation and scheduled tasks
  • Irrigation-zone management included
See E Series →
P
PROFESSIONAL

Recipes, records and environmental coordination

For high-value crops and professional sites. Manage recipes, process workflows, batch records, alarms and connections to climate or farm platforms.

  • 7-inch standard or 10-inch customized interface
  • Recipes, workflows and historical records
  • MQTT / API / Modbus, including ThingsBoard
See P Series →
OEM
WHITE LABEL

Launch your own brand on a proven platform

Distributors and equipment brands can adapt identity, language, interface and connectivity on E, S or P platforms and shorten the path from concept to delivery.

  • Minimum order: 5 units
  • Brand and multilingual adaptation
  • Configuration follows the technical agreement
See OEM →

SERIES COMPARISON

Series capability comparison

S Series and above use dosing algorithms and control circuits designed for the machine, not a generic PLC panel.

CapabilityE EasyS StandardP ProfessionalOEM white label
Core positioningReplace manual workStandardized precise productionProfessional fine managementOwn-brand product
Nutrient channels3–63–63–6Follows base platform
Dosing controlProportional / timedEC / pH closed loopEC / pH closed loopFollows base platform
Operator interfaceStraightforward local control7-inch standard / 10-inch customized7-inch standard / 10-inch customizedCustomizable
Zone managementIncludedIncludedIncludedFollows base platform
Recipes and workflowsFixed processStandard recipes / parametersCustom recipes and process workflowsOptional
Connectivity and recordsOptionalOptional remote managementData capability includedCustomizable
Climate / weather station—Interface reservedCan be integrated*Customizable
Recommended forFarms with a stable processScaled production sitesHigh-value crops / professional sitesDistributors / equipment brands

* P Series climate or weather-station integration requires additional sensors, actuators, gateways or expansion hardware.

MODEL SYSTEM

Clear models, simple ordering

The last two digits are the nutrient-channel count. Choose series and channels to form the public base model. Add -07 or -10 only on quotations for the 7-inch or 10-inch interface.

Base order model PKYDrip-S05

Standard · 5 channels · EC / pH closed-loop fertigation · zone management

7-inch standard touchscreen Final configuration still requires power, pump, mainline flow, valve count and communication options. View product details
E Series photoReplace with E03–E06 product photographyRecommended 4:3, front or 45° view
PKYDrip-E03 / E04 / E05 / E06

E Series · Easy

Turn repetitive manual dosing into a simple, reliable automatic process. Suitable when the fertilizer program is stable and operators need a short learning curve.

Dosing method
Proportional / timed control
Nutrient channels
3–6
Irrigation zones
Included; quantity is project dependent
Typical capability
Pump control, valve control, schedules, alarms
Communication
Local operation; remote communication optional
Typical use
Orchards, greenhouses, fixed-process projects

PKYDrip-E05 · View product details

S Series photo S1Replace with S03–S06 product photographyHighlight the 7-inch screen, channels and pump group
S Series photo S2Replace with S03–S06 product photographyHighlight the 7-inch screen, channels and pump group
PKYDrip-S03 / S04 / S05 / S06

S Series · Standard

The primary machine for repeatable production: integrated cabinet, VFD water supply, zone valves and EC / pH closed-loop control.

Dosing method
EC / pH closed-loop precision control
Nutrient channels
3–6
Operator interface
7-inch standard touchscreen; 10-inch customized option
Core control
VFD, fertilizer valves, zone valves
Sensor configuration
EC / pH standard monitoring; redundancy optional
Typical use
Standard greenhouses, orchards, scaled farms

PKYDrip-S05 · View product details

P Series photoReplace with P03–P06 product photographyInclude the HMI and complete machine
PKYDrip-P03 / P04 / P05 / P06

P Series · Professional

Designed for high-value crops and professional sites. Operators can manage recipes, define process workflows, trace each dosing batch and connect the fertigation system to a larger farm platform.

Dosing method
EC / pH closed loop with recipe control
Nutrient channels
3–6
Operator interface
7-inch standard or 10-inch customized HMI
Data capability
Recipes, batches, trends, logs, alarms
System interfaces
MQTT / API / Modbus; ThingsBoard supported
Expansion
Climate, weather station, remote I/O and custom modules

PKYDrip-P05 · View product details

OEM case photoReplace with a white-label delivery caseHide unauthorized customer information
OEM / ODM · MOQ 5

OEM white-label cooperation

Distributors and equipment brands can form their own product on mature E, S and P platforms, spending time on market and channel instead of repeating controller development.

Minimum order
From 5 units
Base platform
E / S / P series
Brand adaptation
Nameplate, logo, color, packaging
Software adaptation
Language, interface, accounts and cloud
Interface adaptation
Communication and third-party links by agreement
Delivery basis
Prototype approval and signed technical agreement

White-label versions may be based on E, S or P platforms. Minimum order quantity: 5 units. Branding, language, UI, packaging, cloud connection and protocol adaptation require engineering review and a signed technical agreement.

PLANNED SPECIFICATION

Planning values for preliminary selection

Use these figures for product planning and first-pass project selection. Final values are locked after prototype testing and production design freeze.

ParameterE EasyS StandardP Professional
Base modelsE03–E06S03–S06P03–P06
Nutrient channels3 / 4 / 5 / 6 channels
Hydraulic arrangementHydraulic arrangement is project dependent. Standardized mainline and bypass variants confirmed per project configuration.
Reference mainline flowBypass applications typically 10–50 m³/h — preliminary selection only; hydraulic review required
Single-channel dosing classPlanned class up to 600 L/h; actual capacity depends on pressure differential, viscosity, suction piping and calibration
Working pressureRecommended system pressure no more than 4 bar, subject to pump and pipeline design
Control targetProportional / timePlanned EC target ±0.10 mS/cmPlanned EC target ±0.05 to ±0.10 mS/cm; redundant validation optional
pH controlBy configurationClosed-loop regulationClosed-loop regulation; dual-sensor validation optional
SensorsFlow / pressure by configurationOne EC / pH group; redundancy optionalOne EC / pH group; dual EC / pH optional
TouchscreenStraightforward local controller; 7-inch standard / 10-inch customized7-inch standard touchscreen; 10-inch customized option7-inch standard touchscreen; 10-inch customized option
Pump and VFDProject dependentVFD pump control integrated as a core functionVFD pump control linked to process workflows
Irrigation zonesZone management included; local I/O count and expansion quantity are project dependent
CommunicationOptional4G / Wi-Fi / Ethernet / LoRa by configuration4G / Wi-Fi / Ethernet / LoRa, with MQTT / API / Modbus
Power and ratingAC 380 V is a common project configuration; AC 220 V requires evaluation. Total power follows the pump and expansion load.
Protection and dimensionsConfirmed per project configuration and production agreement.

Control targets are system targets and are not the same as the nominal accuracy of one sensor. Fertilizer recipe, mixing time, sensor installation, flow stability and field calibration all affect the result.

PROJECT CONFIGURATION

Confirm the final machine with a configuration sheet

Page values are for first-pass selection. Before a firm order, PKYDrip issues the model, bill of materials and technical agreement from site conditions.

Submit configuration request

This page is a product-planning and sales page. Overall dimensions, total power, protection rating, pump data, channel flow, EC / pH performance, communication fit and expansion quantity follow the frozen production documents and the signed technical agreement. Standardized mainline and bypass model suffixes are confirmed per project configuration.