Short learning curve for operators who currently start pumps, open valves and dose fertilizer by hand.
PKYDrip-E05 · Easy
PKYDrip-E05
Entry automation for replacing repetitive manual irrigation and fertilizer operations. Recommended flagship configuration for precision greenhouse crops, multiple recipes and crop-stage flexibility.
PKYDrip-E05
Why choose this model
This model is specified for a defined operating depth and nutrient-channel count, not as a generic cabinet with one number changed.
Proportional or time-based dosing keeps a stable fertilizer program without requiring closed-loop tuning.
Irrigation-zone management is included so water and fertilizer follow the same local sequence.
Remote communication stays optional, which suits sites that need dependable local operation first.
Five channels are the recommended flagship layout: A + B + A1 + B1 + acid for precision greenhouse recipes.
Application scenarios
Orchards and hoop houses that already have a stable fertilizer recipe and need to stop repeating the same manual sequence.
Projects where operators change often and the control logic must stay obvious on a local panel.
Sites that may add remote access later, but must run correctly with local power and local I/O first.
Recommended flagship configuration for precision greenhouse crops, multiple recipes and crop-stage flexibility.
Key configuration summary
| Product model | PKYDrip-E05 |
|---|---|
| Series | E · Easy |
| Fertilizer channel count | 5 · A + B + A1 + B1 + acid |
| Touchscreen | 7-inch standard touchscreen / 10-inch customized touchscreen |
| Dosing method | Proportional / timed control |
Technical specifications
| Product model | PKYDrip-E05 |
|---|---|
| Series | E · Easy |
| Fertilizer channel count | 5 |
| Dosing method | Proportional / timed control |
| EC control | Proportional / time Planned |
| pH control | By configuration |
| Sensor configuration | Flow / pressure by configuration |
| Touchscreen | 7-inch standard touchscreen / 10-inch customized touchscreen |
| Irrigation-zone management | Irrigation-zone management included; local I/O and expansion quantity are project dependent. |
| Pump and VFD control | Project dependent |
| Mainline reference flow | Bypass applications typically 10–50 m³/h — preliminary selection only; hydraulic review required Typical |
| Working pressure | Recommended system pressure no more than 4 bar, subject to pump and pipeline design Typical |
| Single-channel dosing capability | Planned class up to 600 L/h; actual capacity depends on pressure differential, viscosity, suction piping and calibration Planned |
| Communication | Optional |
| Environmental-control integration | — |
| Weather-station integration | — |
| Power supply | AC 380 V is a common project configuration; AC 220 V requires evaluation. Total power follows the pump and expansion load. Project dependent |
| Overall dimensions | To be confirmed |
| Net weight | To be confirmed |
| Protection rating | To be confirmed |
| Hydraulic arrangement | Hydraulic arrangement is project dependent. Standardized mainline and bypass variants are under development. |
| Installation type | Project dependent |
Control targets are system targets and are not the same as the nominal accuracy of one sensor.
Operation and process
- 01Select the irrigation zone and start the local automatic or timed program.
- 02Dosing channels run by ratio or duration while the pump and valves follow the same sequence.
- 03Alarms stay local unless optional remote communication is specified.
Connectivity and expansion
Local operation is the default. 4G, Wi-Fi, Ethernet or LoRa can be added by configuration. Climate and weather-station integration is not part of the Easy series.
Installation requirements
Provide a level, drained mounting position with access for suction lines, water mains, valves and service clearance.
Confirm incoming power before ordering. AC 380 V is a common project configuration; AC 220 V requires evaluation.
Mainline flow, pressure, fertilizer tank layout and zone-valve count must be submitted for hydraulic and I/O review.
Sensor location, mixing time and field calibration are part of commissioning, not a factory guarantee of one-sensor accuracy.
Optional accessories
10-inch customized touchscreen in place of the 7-inch standard interface
Additional irrigation-zone I/O or remote expansion modules
Redundant EC/pH sensing on S and P series
4G, Wi-Fi, Ethernet or LoRa communication modules
Climate-control and weather-station hardware on P series after engineering review
Downloads
Document placeholder — issued after production design freeze.
Document placeholder — issued after production design freeze.
Document placeholder — issued after production design freeze.
Related models
PKYDrip-E05
Request configuration advice
Specifications are provided for preliminary selection. Final configuration and performance follow the quotation and signed technical agreement.
Specifications are provided for preliminary selection. Final configuration and performance follow the quotation and signed technical agreement.